• Bluelab Wi-fi pH Controller

    708,48  566,78 
    Out of stock

24/7 pH control of your tank anywhere, anytime from your phone

  • Built-in Wi-Fi (with option to disable)
  • View and control from your mobile, visit Edenic.io for more information
  • Safety locks prevent over-dosing
  • Automatic dosing resume after power outage
  • Precise pH adjuster dosing with built-in Bluelab peristaltic pump
  • Control pH in either an up (alkali) or down (acid) direction
  • High/low alarms to alert you when parameters are out of range
  • Dosing routine allows for effective mixing before next dose
  • 2m/6ft cable lengths for better positioning and English: display
  • Built-in variable speed pump. Maximum 120 ml/min (4.06 fl oz)

 

SPECIFICATIONS

Automatic Temperature Compensation: Yes, if the temperature probe is in the same solution as the pH probe
Operating Environment: 0 – 50 ̊C / 32 – 122 ̊F
Measurement Resolution: 0.1 pH
Measuring Range: Control: 0.1 – 13.9 pH. Single direction (up or down). Measurement: 0 – 50 °C / 32 – 122 °F
Measurement accuracy: ± 0.1 pH
Calibration: Two or three points, pH 7.0 and pH 4.0 and/or pH 10.0 calibration
Power: International power supply. The replacement power supply can be purchased separately.
CE Compliance: Yes
FCC Compliance: Yes
RoHS Compliance: Yes 
Dose: up to 120 ml per minute (adjustable).
Display Languages: English, German, Spanish, French and Dutch.

Other Specifications: As a guide, Bluelab recommends the following maximum concentration for commonly used acids and alkalis:
Peristaltic Pump Tubing (PharMed BPT)
Nitric Acid <35%, Phosphoric Acid <85%, Sulfuric Acid <30%, Citric Acid <60%, Potassium Hydroxide <60%, Concentrated Potassium Carbonate, Potassium Silicate <60%.

The following maximum concentrations are recommended for use with Peristaltic Pump Tubing (PharMed BPT). The chemical concentrations listed above are for guidance only. Variations in temperature, pressure or UV exposure may cause tube failure, which could result in serious injury if proper safety precautions are not followed. For this reason, it is recommended that tubes be tested with the desired chemical for the specific application to determine suitability. No warranty (express or implied) is made that the information in these tables is accurate or complete, or that any material is suitable for any purpose.

 

MORE INFORMATION: <a href="https://support.bluelab.com/bluelab-ph-controller-wi-fi?_gl=1*rwf3dh*_gcl_au*MTQ2MTgxODUwMS4xNzI4NTU3MjI 4*_ga*MTA1ODYyMzA4My4xNzI4NTU3MjI4*_ga_HCXKZL6YM3*MTcyODU1NzIyNy4xLjEuMTcyODU1NzI2OS4xOC4wLjA.